HPLC Columns
HPLC Columns
- (63)
- (119)
- (11)
- (50)
- (98)
- (45)
- (28)
- (30)
- (40)
- (28)
- (19)
- (28)
- (27)
- (68)
- (28)
- (22)
- (59)
- (8)
- (85)
- (8)
- (3)
- (74)
- (19)
- (4)
- (53)
- (2)
- (4)
- (2)
- (81)
- (17)
- (68)
- (173)
- (63)
- (7)
- (267)
- (4)
Filtered Search Results
Thermo Scientific™ Hypersil™ BDS C18 Columns
Use as a robust, general-purpose column for a wide range of applications in QC/QA labs.
Carbon Load | 11% |
---|---|
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns
Use as a robust, general-purpose column for QC/QA applications. They are high-quality, base-deactivated, fully endcapped, have similar C18 selectivity but slightly less retentive.
Pore Size | 130 Å |
---|---|
Carbon Load | 7% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L7 |
Thermo Scientific™ Hypersil™ BDS Cyano HPLC Columns
For reliable, general purpose cyano columns, choose the base-deactivated silica Thermo Scientific™ Hypersil™ BDS Cyano LC Columns.
Pore Size | 130 Å |
---|---|
Carbon Load | 4% |
Stationary Phase | Cyano (CN) |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Mixed Mode |
Surface Area | 170 m²/g |
Max. Pressure | 5800 psi (400 bar) |
USP Type | L10 |
Thermo Scientific™ Hypersil™ BDS C8 HPLC Column
For a high-quality, base-deactivated, fully endcapped phase with similar selectivity to C18 but slightly less retention, use Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns.
Pore Size | 130 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 7% |
Stationary Phase | C8 |
Phase | Reversed Phase |
Column Type | Reversed Phase |
Diameter (Metric) | 4.6 mm |
Surface Area | 170 m²/g |
USP Type | L7 |
Column Format | Analytical Column |
Thermo Scientific™ Hypersil™ BDS C18 Column, 5um
For a robust, general-purpose column to use in a wide range of applications, choose Thermo Scientific™ Hypersil™ BDS C18 HPLC Columns.
Pore Size | 130 Å |
---|---|
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Length (Metric) | 300 mm |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
Max. Pressure | 5800 psi (400 bar) |
Column Format | Analytical Column |
Particle Size | 5 μm |
Carbon Load | 11% |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
pH | 2 to 8 |
USP Type | L1 |
Thermo Scientific™ Hypersil™ Phenyl-BDS HPLC Columns
Use as a robust, general-purpose column with aromatic selectivity for QC/QA labs.
Pore Size | 130 Å |
---|---|
Carbon Load | 5% |
Stationary Phase | Phenyl (Ph) |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
Max. Pressure | 5800 psi (400 bar) |
USP Type | L11 |
Thermo Scientific™ Hypersil™ PREP BDS Phenyl HPLC Columns
Achieve unique selectivity for aromatic and slightly polar compounds with a base-deactivated Hypersil PREP Phenyl BDS prep LC column, suitable for USP L11 applications.
Pore Size | 145 Å |
---|---|
Particle Size | 5 μm |
Carbon Load | 5% |
Stationary Phase | Phenyl (Ph) |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 185 m²/g |
USP Type | L11 |
Thermo Scientific™ Hypersil™ PREP BDS C8 HPLC Columns
Scale up to prep LC using Hypersil PREP C8 BDS HPLC columns which offers selectivity similar to C18 but with reduced retention in analytical and preparative scale.
Pore Size | 145 Å |
---|---|
Carbon Load | 7% |
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 185 m²/g |
USP Type | L7 |
Thermo Scientific™ Hypersil™ PREP BDS Si HPLC Columns
Separate nonpolar and moderately polar organic compounds using normal phase Hypersil PREP Si BDS LC columns in preparative scale formats and XtendedLife technology.
Pore Size | 145 Å |
---|---|
Carbon Load | 0% |
Stationary Phase | Silica |
Temperature | 60°C |
Phase | Normal Phase |
Endcapped | No |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
Column Type | Normal Phase |
pH | 2 to 7 |
Surface Area | 185 m²/g |
USP Type | L3 |
Thermo Scientific™ Hypersil™ PREP BDS C18 HPLC Columns
Scale up with Hypersil PREP C18 BDS preparative LC columns for routine applications and C18 retention with base deactivation for reduced silanol activity.
Pore Size | 145 Å |
---|---|
Carbon Load | 11% |
Stationary Phase | C18 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 185 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil™ BDS C18 Column, 3μm
For a robust, general-purpose column to use in a wide range of applications, choose Thermo Scientific™ Hypersil™ BDS C18 HPLC Columns.
Pore Size | 130 Å |
---|---|
Particle Size | 3 μm |
Carbon Load | 11% |
Stationary Phase | C18 |
Phase | Reversed Phase |
Length (Metric) | 125 mm |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 2 to 9 |
Surface Area | 170 m²/g |
USP Type | L1 |
Column Format | Analytical Column |
Thermo Scientific™ Hypersil™ BDS 3μm C18 Columns
A good choice for QA/QC labs as a robust, general-purpose column in applications where reproducibility and long column lifetimes are required
Pore Size | 130 Å |
---|---|
Particle Size | 3 μm |
Carbon Load | 11% |
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil™ BDS C8 Column, 3μm
For a high-quality, base-deactivated, fully endcapped phase with similar selectivity to C18 but slightly less retention, use Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns.
Pore Size | 130 Å |
---|---|
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
Max. Pressure | 5800 psi (400 bar) |
Column Format | Analytical Column |
Particle Size | 3 μm |
Carbon Load | 7% |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
pH | 2 to 8 |
USP Type | L7 |
Thermo Scientific™ Hypersil™ BDS Cyano (CN) Mixed Mode HPLC Column, 5 μm, 4 mm x 300 mm
Column Format: Analytical Column; Carbon Load: 4%; Pore Size: 130 Å; Column Phase: Normal and Reversed Phase
Thermo Scientific™ Hypersil™ BDS Phenyl (Ph) Reversed Phase HPLC Column, 5 μm, 4 mm x 300 mm
Column Format: Analytical Column; Carbon Load: 5%; Pore Size: 130 Å; Column Phase: Reversed Phase