Test
Use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba IIElectronic Pool Tester
Perform both basic and complex analyses with the Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer, an intuitive, reliable solution for education or in the lab.
Photometric Accuracy | ±0.002 A (0 to 0.3 A), 0.5% of ABS reading (0.301 A to 2.5 A) |
---|---|
Connections | USB-A, USB-B |
Scan Speed | Automatic – up to 1200 nm/min. |
Printer Included | Thermal printer accessory with 80 mm width paper |
Noise | ≤0.001A at 0A |
Languages | English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
Detector Type | Silicon Photodiode |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100mm pathlength Available accessory for test-tubes up to 25mm diameter and 150mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Stray Light | <0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
Optical Design | Single Beam |
Photometric Repeatability | ± 0.002 A Measured at 1.0 A at 546 nm |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 1 nm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/250 V, 50/60 Hz |
Warranty | 2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase |
Photometric Range | -3A to +3A |
Wavelength Repeatability | < ±1 nm |
Spectral Bandwidth | 5 nm |
Baseline Flatness | <0.003 A, 325 to 1000 nm, smoothed |
Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
Type | Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5x 38.5x 19.5 cm |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Keypad | Tactile rubber 23 keys with numeric keypad |
Drift | <0.002 A/hr. (At 500 nm after 2 hr. warmup.) Typical <0.004 A/hr. after 1 hr. warmup |
Wavelength Range | 325 to 1100 nm |
Product Line | GENESYS 30 |
Display | 5 in. 32-bit Color Display, 800 x 480 pixels |
Gather accurate chlorine measurements with a colorimeter designed for both the laboratory and the field in markets such as drinking water, wastewater, food & beverage, aquaculture, and agriculture.
Measure common water and wastewater parameters using this colorimeter with 65 pre-programmed methods and auto-test ampoule compatibility.
For use with MC500, MD600, SC450, MD100 colorimeters, SP600 spectrophotometer, Pool Control 9, AquaPRO3 Pool and AquaPRO6 Pool photometers and Scuba II Electronic Pool Tester.
Designed for compatibility with a variety of instruments. Fisherbrand™ Deuterium Lamps are individually tested, certified, and guaranteed to the same specifications as OEM.
Product Type | Deuterium Lamp |
---|
For teaching labs or quality control experts who require ruggedness, ease-of-use and software capability in UV-Vis spectrophotometry.
Used in Waste Water, Drinking Water, Industrial Process Water, Scientific Applications, Governmental and Private Laboratories, Universities and Research Centres, Mobile Applications
Provides accurate and reproducible results very quickly. Lovibond MD 100 Photometer uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. Other features include ease of operation, ergonomic design, compact dimensions and safe handling.
Height (Metric) | 3.5 cm |
---|---|
Accuracy | 3% FS |
Length (Metric) | 15.5 cm |
Display Type | Backlit LCD |
Memory | Internal ring memory for 16 data sets |
Light Source | LED |
Width (Metric) | 7.5 cm |
Weight (Metric) | 260 g |
Resolution | 0.01 A |
includes liquid and tablet reagents, 3 round vials with lids, carry case, batteries and instruction manual
These rugged, waterproof, single parameter colorimeters are ideal for laboratory and field testing
Provides accurate and reproducible results very quickly. Lovibond MD 100 Photometer uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. Other features include ease of operation, ergonomic design, compact dimensions and safe handling.
Provides accurate and reproducible results very quickly. Lovibond MD 100 Photometer uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. Other features include ease of operation, ergonomic design, compact dimensions and safe handling.
Height (Metric) | 3.5 cm |
---|---|
Accuracy | 3% FS |
Length (Metric) | 15.5 cm |
Display Type | Backlit LCD |
Memory | Internal ring memory for 16 data sets |
Light Source | LED |
Width (Metric) | 7.5 cm |
Weight (Metric) | 260 g |
Resolution | 0.01 A |
includes tablet reagents, 3 round vials with lids, carry case, batteries and instruction manual
High-precision, automatic spectrophotometer for objective color measurement
Connections | USB, LAN, RS232 |
---|---|
Height (Metric) | 17 cm |
Width (English) | 20.27 in. |
Length (Metric) | 19.6 cm |
Length (English) | 7.71 in. |
Spectral Bandwidth | 10 nm |
Material | Textured Fabricated Steel |
Languages | English, French, German, Italian, Spanish, Portuguese, Russian, Chinese, Japanese |
Pathlength | 1 x 1, 1 x 5.25 in. |
Calibration | Yes |
For Use With (Application) | Edible oils, fats and transparent liquids |
Light Source | Tungsten Halogen |
Width (Metric) | 51.5 cm |
Includes | Windows™ compatible software, spare lamp, instructions, RCMSi starter pack and Lovibond™ optical Glass cells |
Dimensions (L x W x H) | 7.71 x 20.27 x 6.69 in. (19.6 x 51.5 x 17 cm) |
Voltage | 90/240 V |
Weight (English) | 16.97 lb. |
Certifications/Compliance | CE, RoHS, WEEE |
Wavelength Range | 420 to 710 nm |
Data Storage | 100,000+ Measurements |
Weight (Metric) | 7.7 kg |
Height (English) | 6.69 in. |
Display | Backlit LCD |