Conductivity Meters
Conductivity Meters
- (7)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (3)
- (2)
- (1)
- (1)
- (2)
- (3)
- (2)
- (2)
- (1)
- (1)
- (3)
- (6)
- (11)
- (1)
- (2)
- (4)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (3)
- (3)
- (1)
- (1)
- (8)
- (35)
- (1)
- (1)
- (2)
- (3)
- (1)
- (5)
- (1)
- (7)
- (3)
- (18)
- (2)
- (7)
- (1)
- (6)
- (1)
- (1)
- (1)
- (2)
- (5)
- (1)
- (30)
- (5)
- (1)
- (2)
- (11)
- (16)
- (6)
- (18)
- (14)
- (6)
- (1)
- (10)
- (1)
- (3)
- (6)
- (1)
- (1)
- (2)
- (11)
- (2)
- (1)
- (1)
Filtered Search Results
Fisherbrand™ Traceable™ Expanded Range Conductivity Meter
Ideal for checking the purity of water from stills, deionizers, and reverse osmosis, testing laboratory glassware rinsing, measuring total dissolved solids, and making solutions.
accumet™ AET30 Conductivity Tester
accumet AET30 Conductivity Tester, Calibration Points: Three auto or three manual, Range: to 200.0uS/cmto 2,000uS/cmto 20.00mS/cm, 0 to 50.0 deg.C/32.0 to 122 deg.F, Accuracy: +/- 1% of full scale, +/- 0.5 deg.C+/- 0.9 deg.F + 1 LSD, Battery Life: More than 150 hours
Fisherbrand™ Traceable™ Dual-Display Conductivity Meter
Measures conductivity and temperature; includes NIST™ traceability certificate.
Thermo Scientific™ Eutech™ CON 150 Conductivity Meter
Get quick and accurate conductivity measurements in the field, laboratories, and schools.
Thermo Scientific™ Eutech™ ECOTDSTESTLOW TDS Meter
Get quick and accurate Total Dissolved Solids (TDS) measurements in the field, laboratories, and schools.
Thermo Scientific™ Eutech™ CON 150 Conductivity Meter
Get quick and accurate conductivity measurements in the field, laboratories, and schools.
Jenway™ Bench pH/Conductivity Meter 3540
Ideal for use in all laboratories where pH and conductivity analyses are required. The setup menu gives quick and easy access to the whole range of instrument, pH and conductivity measurement options.
Jenway™ Conductivity Meter
Easy-to-use, broadly applicable conductivity meter. Jenway™ Conductivity Meter features automatic conductivity standard recognition and endpoint detection.
Thermo Scientific™ Eutech™ ECOECTESTHIGH Conductivity Meter
The Eutech EcoTestr EC series comes with rugged, sturdy stainless steel pin sensors, giving you quick, reliable conductivity measurements.
Fisherbrand™ Traceable™ Conductivity Meter Pen
Easy-to-use, waterproof conductivity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Thermo Eutech™ COND 6+ Conductivity Meter
COND 6+ Conductivity Meter, Rubber Armour/Stand, electrode CONSEN91B
Thermo Scientific™ Eutech COND 6+ Handheld Meter Kit with Electrode
Lightweight, economical, and efficient handheld meters
Fisherbrand™ Traceable™ Conductivity/TDS Meter Pen
Easy-to-use, waterproof conductivity/TDS meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.
Thermo Scientific™ Orion Lab Star EC112 Conductivity Bench Meters
Orion Lab Star EC112 conductivity bench meters measure conductivity, salinity or TDS with temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. This conductivity meter is ideal for simplified, budget-friendly lab testing and data recording.
Salinity Measurement Modes | Natural Seawater (ppt) or Practical Salinity (PSU) |
---|---|
Memory | Non-volatile |
Cell Constant | 0.100 to 10.00 cm-1 |
Measurement Modes | Conductivity with Temperature,Salinity with Temperature,TDS with Temperature |
Temperature (Metric) Reference | 15.0, 20.0, 25.0 or 30.0°C |
Temperature Coefficient | 0 to 10 %/°C |
TDS Factor Range | 0.40 to 1.00 |
Range (Salinity) | 0.00 to 80.0 ppt; 0.00 to 42.0 PSU |
Data Management Details | Continuous, Auto-Read and Timed read modes |
Temperature Compensation | Linear (0 to 10 %/°C) or off |
Display Type | 5 in. backlit LCD |
Accuracy (Salinity) | ±0.5 % of the reading ± 1 LSD |
Resolution (Salinity) | 0.01, 0.1 ppt; 0.01, 0.1 PSU |
Accuracy (Conductivity) | ±0.5 % of the reading ± 1 LSD |
Data Points | 500 data sets with time and date |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 point temperature offset calibration |
Inputs | 8-pin MiniDIN for conductivity with built-in ATC |
Accuracy (Temperature) | ±0.3°C, ±0.5°F |
Weight (Metric) | 700 grams |
Calibration Points (Conductivity) | 1-5 points conductivity |
Warranty | 3 year meter warranty |
Resolution (Conductivity) | 0.01, 0.1, 1 μS; 0.01, 0.1 mS |
Range (Conductivity) | 0.00 μS to 500.0 mS |
AC Adapter | Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Log Function Type | Automatic with Auto-Read and Timed read modes, manual with Continuous read mode |
Resolution (TDS) | 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt |
Calibration | Conductivity, salinity, TDS and temperature |
Calibration Points | 1 point salinity, 1-5 points TDS, 1 point temperature |
Alarm Output | Calibration reminder alarm |
Dimensions (L x W x H) | 187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in. |
Accuracy (TDS) | ±0.5 % of the reading ± 1 LSD |
IP Rating | IP54 |
Temperature Selection | Manual or automatic with ATC temperature probe |
Outputs | Computer or printer (STARA-106) |
Backlight Option | Yes |
Temperature Range (English) | 23.0°F to 221.0°F |
Weight (English) | 1.54 lb. |
Resolution (Temperature) | 0.1°C, 0.1°F |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Compatible Probes | 2-cell and 4-cell conductivity electrodes |
Thermo Scientific™ Orion Star™ A212 Conductivity Benchtop Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Reliably measure conductivity, TDS, salinity, resistivity and temperature with this conductivity benchtop meter for advanced lab analysis.
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
---|---|
Range (Resistivity) | 2 ohm to 100.0 megohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
Battery Life | 800 hr. |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Graphic LCD with Backlight |
Data Points | 2000 with date and time stamp |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 point temperature offset calibration |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Warranty | 3 Year Meter |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Battery Type | 4 x AA (sold separately) |
Relative Humidity Range | 5 to 85%, non-condensing |
Dimensions (L x W x H) | 24 x 18 x 11 cm (9.5 x 7.1 x 4.3 in.) |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Backlight Option | Yes, selectable |
Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
Methods | 10 per channel with password protection |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
Channels | 1 |
TDS Factor Range | Linear (0.02 to 9.99) |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.1°C |
Weight (Metric) | 0.9 kg |
Calibration Points (Conductivity) | 5 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | Conductivity with calibration editing option and temperature |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP54 |
Model | Orion Star A212 Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter |
Weight (English) | 2 lb. |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5°C to +105°C |