missing translation for 'onlineSavingsMsg'
Learn More

HepG2/C3A (human hepatoblastoma) Nuclear extract lysate, Non-denatured; Abnova

Brand:  Abnova L019V4.50ug

Product Code. 16049555

  • 215.00€ / 50µg
Estimated Shipment: 29-01-2025
to see stock.
Explore more special offers
Add to basket
This item is not returnable. View return policy

Description

Description

  • Tissue: Liver
  • Host: Human
  • Lysis buffer: Buffer A (10mM HEPES pH 7.9, 1.5mM MgCl2, 10mM KCl, 0.5 mM DTT), Buffer C (20mM HEPES pH 7.9, 25%(v/v) Glycerol , 0.42M NaCl , 1.5mM MgCl2, 0.2mM EDTA, 0.5mM DTT & 0.5mM PMSF), Buffer D (20mM HEPES pH 7.9, 20%(v/v) glycerol, 50mM KCl, 0.2mM EDTA, 0.5mM DTT & 0.5mM PMSF)
  • Storage buffer: In buffer D

Applications:

Western Blotting, Immunoprecipitation

Specifications

Specifications

Immunoprecipitation, Western Blot
Nuclear extract cell lysate (non-denatured)
Nuclear extract was prepared by using a modified protocol of Dignam et al. Cells were Harvested and homogenized in Buffer A, and then centrifugated at 25,000 g for 20 minutes to remove cytoplasm and pellet the nuclei. The pellet was re-suspended in Buffer C, and then the suspensions were centrifuged to collect nuclear extract. The supernatant was dialyzed against Buffer D. The dialysate was then centrifuged, divided into aliquots, and stored at -80°C. The protein concentration was determined by the method of Bradford (Bio-Rad protein assay, microplate standard assay). The lysate was adjusted to 2 mg/ml.
50 μg
Human
Store at -80°C. Aliquot to avoid repeated freezing and thawing.
Liver
Buffer A: 10mM HEPES pH 7.9, 1.5mM MgCl2, 10mM KCl, 0.5 mM DTT. Buffer C: 20mM HEPES pH 7.9, 25%(v/v) Glycerol , 0.42M NaCl , 1.5mM MgCl2, 0.2 mM EDTA, 0.5 mM DTT & 0.5 mM PMSF. Buffer D : 20mM HEPES pH 7.9, 20%(v/v) glycerol, 50mM KCl, 0.2 mM EDTA, 0.5 mM DTT & 0.5 mM PMSF.
12.5% SDS-PAGE Stained with Coomassie Blue.
In Buffer D.
2.5 mg/mL
Product Suggestions

Product Suggestions

Videos
SDS
Documents

Documents

Certificates
Special Offers

Special Offers

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.