missing translation for 'onlineSavingsMsg'
Learn More

Applied Biosystems™ MagMAX™-96 AI/ND Viral RNA Isolation Kit

The Applied Biosystems™ MagMAX™-96 AI/ND Viral RNA Isolation Kit is for the isolation of viral RNA and DNA from diverse sample types (i.e., environmental samples and biofluids). Nucleic acids purified using this kit are ideal for PCR and RT-PCR. applications.

Brand:  Applied Biosystems™ AM1835

1982.75 EUR valid until 2024-11-30
Use promo code "21651" to get your promotional price.


Product Code. 30054625

  • 3605.00€ / Pack of 384
Estimated Shipment: 13-12-2024
to see stock.
Explore more special offers
Add to basket
This item is not returnable. View return policy

Description

Description

The MagMAX™-96 AI/ND Viral RNA Isolation Kit is a first generation MagMAX™ Viral RNA Isolation Kit validated by the NVSL for use with AI/ND viruses. Perfect for working with low viral concentrations, the kit contains sufficient reagents for 4 x 96 reactions.

  • Validated by the NVSL for use with AI/ND viruses
  • Recover as few as 10 copies of viral RNA from 100 to 400 μL sample
  • Typical viral RNA recovery of >50%
  • Ideal when working with low viral concentrations
  • Linear recovery down to 50 transcripts
  • 96 samples can be processed in 30 minutes
  • Easily integrated into robotic platforms

Benefits of MagMAX™ Magnetic Bead-Based Purification:

Magnetic beads offer many benefits compared to other technologies for isolating RNA. Beads bind RNA more efficiently than glass fiber filters, resulting in higher and more consistent RNA yields. Additionally, because filters are not used, there is no risk of filter clogging due to cellular particulates in samples. Since only a small volume of magnetic beads is needed for high-efficiency binding, the bound RNA can be eluted in just 20 to 50 μL of nuclease-free water, concentrating RNA from large, dilute samples.

Optimized for Isolation of Virus from Biofluids:

The Applied Biosystems™ MagMAX™ Viral RNA Isolation Kit has been optimized for use with biological fluids and cell-free samples such as serum, plasma, swabs, and cell culture media. These samples often present unique challenges when purifying RNA, including low viral titers, large volumes to be processed, and sample complexity. Without the need for organic solvents or RNA precipitation, the MagMAX™ Viral RNA isolation kit eliminates the problems often encountered with other RNA isolation methods such filter clogging, large elution volumes, and inconsistent yields.

Get the Same Amount of RNA from 10-fold Less Sample

The sensitivity of viral RNA detection was compared using RNA isolated with Applied Biosystems™ MagMAX™ protocol or the current National Veterinary Services Laboratories (NVSL) validated viral testing protocol. Even at one-tenth the sample input, viral RNA isolated using the MagMAX™ kit could be detected at equal or greater levels than RNA isolated using the NVSL protocol and recommended competitor's kit.

Accessory Products:

Carrier RNA (SKU#4382878), Lysis/Binding Solution Concentrate (SKU#AM8500), Wash Solution 1 Concentrate (SKU#AM8504), and Wash Solution 2 Concentrate (SKU#AM8640) are components of the MagMAX™ Viral RNA Isolation Kits that may also be purchased separately. A 96-well magnetic ring stand is required to use this kit. The Magnetic Stand-96 (SKU#AM10027) and the 96-well Magnetic Ring Stand (SKU#AM10050) are designed for paramagnetic bead precipitation from standard 96 well U-bottom microplates. The Magnetic-Ring Stand pellets the magnetic beads in a circle shape, enabling easy removal of supernatant by a robot or multichannel pipettors. For additional processing plates, Matrix 96-Well U Bottom Polypropylene Plates (Thermo Scientific, Item# 4917) are recommended. The MagMAX™ and MagMAX™-96 Viral RNA Isolation Kits (SKU#AM1939 and SKU#AM1836) are the newest generation MagMAX™ kits for this application, but are not yet validated by the NVSL.

TRUSTED_SUSTAINABILITY
Specifications

Specifications

Carrier RNA is stored at –20°C; RNA Binding Beads are stored at 4°C. Wash Solution 2 Concentrate and Elution Buffer may be stored at either 4°C or room temperature. Lysis⁄Binding Solution Concentrate, Wash Solution 1 Concentrate, RNA Rebinding Concentrate, Bead Resuspension Solution, Processing Plates and Lids, and PBS Buffer are stored at room temperature. Nuclease-free water may be stored at any temperature.
Magnetic Bead
Liquid Samples (e.g. Serum), Viral Samples
High-throughput Compatible, Not High-throughput Compatible (Manual), Automated Protocols
Real-Time Quantitative PCR (qPCR), Reverse Transcriptase PCR (RT-PCR), Northern Blotting
MagMAX™
Viral DNA/RNA
96-well Plate
1 hr.
Viral RNA
KingFisher™ Flex Magnetic Particle Processor, KingFisher 96, MagMAX™ Express-96 Standard Magnetic Particle Processor
384 preps
Up to 50μl of sample
5 ng
Product Suggestions

Product Suggestions

Videos
SDS
Documents

Documents

Certificates
Special Offers

Special Offers

For Veterinary Use Only.