Electrochemistry Meters

Electrochemistry Meters









Thermo Scientific™ Orion Star™ A214 pH/ISE Benchtop Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More

Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Reliably measure pH, ion concentration, mV, ORP and temperature with our pH/ISE benchtop meter for advanced lab analysis and interfacing.
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
---|---|
Advanced ISE Functions | Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature |
Resolution (ISE) | 0.0001 minimum, 1 to 3 significant digits (user selectable) |
Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
Data Management Details | Transfer single, range or all data points to printer or computer |
Battery Life | 800 hr. |
Display Type | LCD Graphic, Backlit |
Resolution (mV) | 0.1mV |
Data Points | 2000 with date and time stamp |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Warranty | 3 Year Meter |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Calibration Points (ISE) | 1 to 5 |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Battery Type | 4 AA (sold separately) |
Relative Humidity Range | 5 to 85 %, non-condensing |
Dimensions (L x W x H) | 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.) |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 5 |
Backlight Option | Yes, selectable |
Range (mV) | ±2000.0 mV |
Range (ORP) | ±2000.0 mV |
Methods | 10 per channel with password protection |
Range (pH) | -2.000 to 20.000 |
Channels | 1 |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none |
Inputs | BNC (pH, ORP or ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) |
Weight (Metric) | 0.9 kg |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Isopotential Point | 7.000pH |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP 54 |
Model | Orion Star A214 pH/ISE/mV/RmV/ORP/Temperature Benchtop Meter |
Weight (English) | 2 lb. |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Temperature Resolution | 0.1°C, 0.1°F |
METTLER TOLEDO™ SevenExcellence™ S475 pH/Conductivity/ISE Benchtop Meter
The S475 meter performs pH, conductivity, resistivity, ion selective, salinity, TDS, Redox/ORP, and ISFET measurements. It can be expanded with an additional module to measure DO/BOD. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel, or LIMS system.
Thermo Scientific™ Orion Lab Star EC112 Conductivity Bench Meters
Orion Lab Star EC112 conductivity bench meters measure conductivity, salinity or TDS with temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. This conductivity meter is ideal for simplified, budget-friendly lab testing and data recording.
Salinity Measurement Modes | Natural Seawater (ppt) or Practical Salinity (PSU) |
---|---|
Memory | Non-volatile |
Cell Constant | 0.100 to 10.00 cm-1 |
Measurement Modes | Conductivity with Temperature,Salinity with Temperature,TDS with Temperature |
Temperature (Metric) Reference | 15.0, 20.0, 25.0 or 30.0°C |
Temperature Coefficient | 0 to 10 %/°C |
TDS Factor Range | 0.40 to 1.00 |
Range (Salinity) | 0.00 to 80.0 ppt; 0.00 to 42.0 PSU |
Data Management Details | Continuous, Auto-Read and Timed read modes |
Temperature Compensation | Linear (0 to 10 %/°C) or off |
Display Type | 5 in. backlit LCD |
Accuracy (Salinity) | ±0.5 % of the reading ± 1 LSD |
Resolution (Salinity) | 0.01, 0.1 ppt; 0.01, 0.1 PSU |
Accuracy (Conductivity) | ±0.5 % of the reading ± 1 LSD |
Data Points | 500 data sets with time and date |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 point temperature offset calibration |
Inputs | 8-pin MiniDIN for conductivity with built-in ATC |
Accuracy (Temperature) | ±0.3°C, ±0.5°F |
Weight (Metric) | 700 grams |
Calibration Points (Conductivity) | 1-5 points conductivity |
Warranty | 3 year meter warranty |
Resolution (Conductivity) | 0.01, 0.1, 1 μS; 0.01, 0.1 mS |
Range (Conductivity) | 0.00 μS to 500.0 mS |
AC Adapter | Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Log Function Type | Automatic with Auto-Read and Timed read modes, manual with Continuous read mode |
Resolution (TDS) | 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt |
Calibration | Conductivity, salinity, TDS and temperature |
Calibration Points | 1 point salinity, 1-5 points TDS, 1 point temperature |
Alarm Output | Calibration reminder alarm |
Dimensions (L x W x H) | 187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in. |
Accuracy (TDS) | ±0.5 % of the reading ± 1 LSD |
IP Rating | IP54 |
Temperature Selection | Manual or automatic with ATC temperature probe |
Outputs | Computer or printer (STARA-106) |
Backlight Option | Yes |
Temperature Range (English) | 23.0°F to 221.0°F |
Weight (English) | 1.54 lb. |
Resolution (Temperature) | 0.1°C, 0.1°F |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Compatible Probes | 2-cell and 4-cell conductivity electrodes |
METTLER TOLEDO™ SevenExcellence™ S470 pH/Conductivity Benchtop Meter
The S470 meter measures pH, conductivity, resistivity, redox/ORP, TDS, salinity, and ISFET. It can be expanded with additional modules to measure dissolved oxygen, BOD, and ISE. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel file, or LIMS system.
Range (Resistivity) | 0.01 to 100 Mohm/cm |
---|---|
Resolution (pH) | 0.001/0.01/0.1 |
Range (pH) | -2 to 20 |
Resolution (ISE) | 0.001 to 1 |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0 to 999999mg/L |
Range (Salinity) | 0 to 80 ppt |
Display Type | TFT |
Resolution (Salinity) | 0.001 to 1 |
Accuracy (Conductivity) | ±0.5% |
Resolution (mV) | 0.1/1mV |
Data Points | 20,000 |
Calibration Points (Conductivity) | 13 Pre defined and 20 user defined standard |
Accuracy (mV) | ±0.1mV |
Temperature Accuracy | ±0.1°C |
Calibration Points (ISE) | Max. 5 points, 8 pre defined and 20 user defined buffer group |
Resolution (Resistivity) | 0.001 to 1 |
Resolution (Conductivity) | 0.001μS/cm to 2000mS/cm |
Range (Conductivity) | 0.001 μS/cm to 2000 mS/cm |
Range (TDS) | 0.001 mg/L to 1000 g/L |
Resolution (TDS) | 0.001 to 1 |
Outputs | RS232, USB-A, USB-B, LAN, Mini-LTW, Mini-DIN, BNC, Cinch/RCA |
Calibration Points (pH) | Max. 5 points, 8 pre defined and 20 user defined buffer group |
Temperature Range (Metric) | -30°C to +130°C |
Range (mV) | -2000 to 2000 mV |
Temperature Resolution | 0.1°C |
METTLER TOLEDO™ S479 SevenExcellence™ pH/Conductivity/DO Benchtop Meter Kit
The S479 meter kit gives you everything you need to start measuring pH, conductivity, dissolved oxygen, BOD, resistivity, salinity, TDS, Redox/ORP, and ISFET all on one meter. It has an intuitive touchscreen, measurement shortcuts, and can export data to a printer, Excel file, or LIMS system.
Thermo Scientific™ Orion™ Versa Star Pro™ pH/ISE/Conductivity/Dissolved Oxygen Multiparameter Benchtop Meter
SureTRACE
Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More

Supports traceability with guaranteed access to certificates and proactive change notifications.
Learn More
Get premium performance and flexibility with our multiparameter benchtop meter with pH/ISE, conductivity and RDO/DO modules to measure up to four channels at once.
Power Rating | DC input: 9VDC, 1A |
---|---|
Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
Resolution (Polarographic DO) | 0.01, 0.1mg/L |
Pressure Range | 400 to 850mmHg |
Range (Resistivity) | 2 ohm to 100.0 meg-ohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Resolution (pH) | 0.1/0.01/0.001 |
Languages | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Measurement Modes | pH,mV,Relative mV,ORP,Ion Concentration (ISE) with Temperature,TDS,Conductivity,Salinity |
Resolution (ISE) | 0.0001 minimum, 1 to 4 significant digits (user selectable) |
Power Supply | Universal AC adapter (included) |
Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Color graphic LCD with user-customizable options |
Resolution (mV) | 0.1mV |
Data Points | 2000 with date and time stamp |
Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
Temperature Probe Calibration | 1 point temperature offset calibration |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Salinity Factor | 0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity |
Accuracy (mV) | ±0.2 mV or ±0.05% of reading whichever is greater |
Accuracy (ISE) | ±0.2 mV or ±0.05% of reading whichever is greater |
Temperature Accuracy | ±0.1°C |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Calibration Points (ISE) | 1 to 6 |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with |
Percent Saturation Range Polarographic DO | 0.0 to 600.0% saturation |
Relative Humidity Range | 5 to 85%, non-condensing |
Range (RDO) | 0.00 to 50.00mg/L |
Dimensions (L x W x H) | 28 x 24 x 10cm (11 x 9.5 x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Percent Saturation Range (RDO) | 0.0 to 500.0% saturation |
Keypad | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB (2), RS232 |
Temperature Range (English) | 22.0°F to 221.0° F |
Range (Relative mV) | ±2000.0 mV |
Calibration Points (pH) | 1 to 6 |
Backlight Option | Yes |
Percent Saturation Relative Accuracy (RDO) | ±2% saturation ≤ 200% saturation, ±10% saturation > 200% saturation |
Range (Polarographic DO) | 0.00 to 90.00mg/L |
Range (mV) | ±2000.0 mV |
Accuracy (Barometer) | ±6 mmHg |
Range (ORP) | ±2000.0 mV |
Pressure Resolution | 0.1mmHg |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5°, 10°, 15°, 20°, 25°C |
Range (pH) | -2.000 to 20.000 |
TDS Factor Range | Linear (0.02 to 9.99) |
Channels | 4 - customizable with modules |
Accuracy (pH) | ±0.002 |
Range (ISE) | 0.0001 to 19990 with selectable units of ppm, Molar, mg/L, %, ppb or none |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Resolution (RDO) | 0.01, 0.1mg/L |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Percent Saturation Resolution (RDO) | 0.1, 1% saturation |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS |
Weight (Metric) | 1.2 kg, modules add 0.2 kg each |
Calibration Points (Conductivity) | Up to 6 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 meg-ohm, auto ranging |
Isopotential Point | 7.000pH (adjustable), 1.000 ISE (adjustable) |
Accuracy (Polarographic DO) | ±0.2 mg/L or ±2% of reading, whichever is greater |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Range (TDS) | 0.001 ppm to 200.0 ppt |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ |
Calibration Points | 1 point relative mV (RmV) mode, 1 point ORP mode |
Alarm Output | Set point alarm, high/low limit alarm, calibration due alarm |
IP Rating | IP 54 |
Percent Saturation Resolution (Polarographic DO) | 0.1, 1% saturation |
Weight (English) | 2.5 lb., modules add 0.5 lb. each |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Percent Saturation Range (Polarographic DO) | 0.0 to 600.0% saturation |
Temperature Resolution | 0.1°C, 0.1°F |
Accuracy (RDO) | ±0.1 mg/L up to 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of reading up to 50 mg/L |
Fisherbrand™ accumet™ AB200 Benchtop pH/Conductivity Meters
Provides intuitive, simple operation and high accuracy measurements in a compact, affordable meter. Fisherbrand accumet AB200 pH/conductivity meter combines the benefits of a pH meter and conductivity meter in one easy to use, reliable measurement system. The large backlit display offers great visibility in laboratory environments.
Range (Resistivity) | 2 W to 20 MW |
---|---|
Resolution (pH) | 0.1/0.01/0.001 |
Cell Constant | 0.010 to 10.000 |
Range (pH) | -2 to 20 |
Accuracy (pH) | ±0.002 |
Range (Salinity) | 0 to 80 ppt |
Data Management Details | Manual, timed (selectable every 3 to 3600 sec.), printer or CSV format |
Display Type | LCD |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240V |
Accuracy (Conductivity) | ±1% FS |
Resolution (mV) | 0.1mV |
Data Points | 500 |
Inputs | BNC, ATC |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Accuracy (mV) | ±0.2 mV |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Resolution (Conductivity) | 0.01/0.1μS, 0.001/0.01/0.1mS |
Range (Conductivity) | 0 μS to 500 mS |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0 ppm to 500 ppt (at TDS factor 1) |
Resolution (TDS) | 0/0.1ppm, 001/01/0.1ppt |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232 (phono plug), mini-B USB, stirrer |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Fisherbrand™ accumet™ Basic AB330 Benchtop Laboratory Conductivity Meter
Ideal for daily conductivity, TDS and salinity testing of your routine laboratory samples, the accumet™ Basic AB330 Benchtop Meter provides essential functions needed without complicated functions at a budget-friendly price.
Memory | Non-volatile |
---|---|
Cell Constant | 0.1 to 10 |
Measurement Modes | Conductivity with Temperature,TDS with Temperature,Salinity with Temperature |
Temperature (Metric) Reference | 15, 20, 25 or 30°C |
Temperature Coefficient | 0 to 10 %/°C |
TDS Factor Range | 0.4 to 1 |
Range (Salinity) | 0 to 80 ppt |
Data Management Details | Printed or CSV Format |
Temperature Compensation | Linear |
Display Type | 5 in. LCD |
Accuracy (Salinity) | ±1% Full Scale |
Resolution (Salinity) | 0.01, 0.1 ppt |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±1% Full Scale |
Data Points | 500 Points |
Inputs | Conductivity, ATC |
Accuracy (Temperature) | ±0.3°C (±0.5°F) |
Calibration Points (Conductivity) | 84 μS, 1413 μS, 12.88 mS, 111.8 mS |
Stability | Indicator Icons |
Warranty | 3 Years |
Resolution (Conductivity) | 0.01, 0.1, 1 μS; 0.01, 0.1 mS |
Range (Conductivity) | 0 μS to 500 mS |
AC Adapter | Universal Power Adapter |
Resolution (TDS) | 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt |
Calibration | Conductivity, TDS, Salinity, Temperature |
Calibration Points | 1 to 5 (Conductivity), 1 to 5 (TDS), 1 (Salinity), 1 (Temperature) |
Accuracy (TDS) | ±1% Full Scale |
IP Rating | IP54 |
Data Logging | Automatic with Auto-read and Timed Modes, Manual with Continuous Mode |
Model | AB330 |
Outputs | Port for Computer or Printer |
Frequency | 50/60 Hz |
Backlight Option | Yes |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature Range (Metric) | -5°C to +105°C |
Oakton™ pH 700, CON 700, pH-CON 700 pH/Conductivity Benchtop Meters, Measures conductivity, TDS and temperature
An affordable way to take consistent, accurate conductivity measurements in your laboratory.
Warranty | 3 Years |
---|---|
Temperature Compensation | Automatic or manual from 0° to 100°C |
Display Type | LCD |
Voltage | 120/240V |
Fisherbrand™ accumet™ XL500 Benchtop Dual pH/ISE and Conductivity Meters
Provide advanced measurements with simple operation and offer a large, vivid color touch-screen display that allows for dynamic functionality. Fisherbrand accumet XL500 dual pH/ISE/conductivity benchtop meters offer advanced features with simple operation to help ensure your measurements are reliable and your laboratory processes are efficient.
Length (Metric) | 24.6 cm |
---|---|
Range (Resistivity) | 3 W to 100 MW over 4 ranges: 0 to 20 kW, 20 to 200 kW, 200 kW to 2 MW, 2 to 100 MW |
Detection Range | Multiple |
Length (English) | 9.68 in. |
Resolution (pH) | 0.1/0.01/0.001 |
Cell Constant | 0.01 to 10 |
Range (pH) | -2 to 20 |
Width (Metric) | 17.3 cm |
Resolution (ISE) | 2/3/4 Digits |
Accuracy (pH) | ±0.002 |
Range (ISE) | ±2000 mV |
Range (Salinity) | 0 to 80 ppt |
Accuracy | Multiple |
Data Management Details | 3 to 86400 sec. |
Display Type | LCD |
Accuracy (Salinity) | ± 1% full scale |
Resolution (Salinity) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Voltage | 100/240V |
Accuracy (Conductivity) | ±1% FS |
Resolution (mV) | 0.1mV |
Data Points | 2000 |
Certifications/Compliance | NIST, ISO, FDA, USDA, EPA |
Inputs | 2 BNC, 2 ATC |
Weight (Metric) | 1.13 kg |
Height (English) | 3.89 in. |
Calibration Points (Conductivity) | Automatic (4 points), maximum 1/range, manual (5 points), maximum 1/range |
Height (Metric) | 9.9 cm |
Accuracy (mV) | ±0.2 mV |
Accuracy (ISE) | 0.5% full scale (monovalent ion), 1% full scale (divalent ion) |
Warranty | 3 Years |
Temperature Accuracy | ±0.3°C |
Calibration Points (ISE) | 2 to 6 |
Resolution (Resistivity) | 0.01/0.1W, 0.001/0.1kW, 0.01MW |
Resolution (Conductivity) | 0.001/0.01/0.1mS |
Range (Conductivity) | 0 to 500 mS |
Accuracy (Resistivity) | ± 1% full scale |
Range (TDS) | 0.050 ppm to 500 ppt (at TDS factor 1.00) |
Resolution (TDS) | 0.01/0.1ppm, 0.001/0.01/0.1ppt |
Dimensions (L x W x H) | 24.6 x 17.3 x 9.9cm (9.7 x 6.8 x 3.9 in.) |
Accuracy (TDS) | ± 1% full scale |
Outputs | RS232, USB-A, Mini-B USB, RJ45, stirrer port (2) |
Frequency | 50/60Hz |
Calibration Points (pH) | Up to 6 preset or 5 custom |
Weight (English) | 2.5 lb. |
Range (mV) | ±2000 mV |
Temperature Resolution | 0.1°C |
Resolution | Multiple |
Mettler Toledo™ FiveEasy™ Plus FP30 Conductivity Meters
Compact, benchtop meter provides high quality conductivity measurements with simple click of a button
Resolution (Conductivity) | Automatic range |
---|---|
Memory | 200 measurements, current calibration |
Range (Conductivity) | 0.01 μS/cm to 500 mS/cm |
Calibration | One point calibration with three predefined standards, manual cell constant input |
Dimensions (L x W x H) | 22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.) |
Data Management Details | RS232 or USB ports |
Temperature Compensation | Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C |
Voltage | 100/240V |
Accuracy (Conductivity) | ±0.5% of the measured value |
Frequency | 50/60Hz |
Temperature Range (English) | 32°F to 212°F |
Weight (English) | 1.4 lb. |
Resolution (Temperature) | 0.1°C |
Inputs | Mini-DIN |
Accuracy (Temperature) | 0.3°C |
Weight (Metric) | 0.63 kg |
Mettler Toledo™ S975 SevenExcellence™ pH/Conductivity/Ion/DO Meter Kit
Professional modular triple-channel instrument for measuring ion concentrations, pH, mV/ORP, rel. mV, conductivity, salinity, TDS, resistivity and conductivity ash
Jenway™ Conductivity Meter
Easy-to-use, broadly applicable conductivity meter. Jenway™ Conductivity Meter features automatic conductivity standard recognition and endpoint detection.
Thermo Scientific™ Eutech™ PC 450 Multi-parameter Meter Kit
Measure multiple parameters in a cost-effective and convenient way by using only one Eutech™ multi-parameter meter.
Thermo Eutech™ COND 6+ Conductivity Meter
COND 6+ Conductivity Meter, Rubber Armour/Stand, electrode CONSEN91B