Filtered Search Results
Fisherbrand™ Aspiration Advantage System
Compact and portable unit with an integrated resistant diaphragm pump, used for the safe and precise aspiration of non-flammable chemical, biological, and medical liquids. Fluids can be removed easily and very precisely from slides, petri dishes, microplates, cell culture containers or similar vessels by using different pipettes or glass tips which can be easily connected to the HandVac pipettor attachment.
Fisherbrand™ Two-Stage Rotary Vane Pump FRVP Series
Rugged, must-have pumps for deep vacuum operation give high reliability and low maintenance operation in a wide range of lab and industrial applications
Noise Level | < 50dB(A) |
---|---|
Electrical Requirements | 230 V, 50/60 Hz |
For Use With | Deep vacuum operation |
Applications | Chemistry: Schlenk lines, glove boxes, Life sciences: freeze dryers, vacuum concentrators, vacuum ovens (<0.1 mbar), Industrial: vacuum furnaces, isolation vacuums, Analytical: as replacement backing pumps for mass spectrometers, General R&D: for evacuation of vacuum systems and chambers down to fine vacuum levels (10-3mbar) |
Voltage | 230 V |
Pump Type | Two-stage Rotary Vane Vacuum Pump |
VACUUBRAND™ Chemistry Pumping Unit, PC 3001 VARIO select
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Provides pinpoint vacuum control by adjusting the motor speed. Automatic evaporation mode is perfect for controlling applications such as rotary evaporation. Various condenser types are available to meet a range of desired applications.
Enclosure Rating | IP20 |
---|---|
Electrical Requirements | 200/230 V, 50-60 Hz and 100/120 V, 50-60 Hz |
Temperature (Metric) Max | 40°C |
Wattage | 0.16 kW |
Material | PTFE (Partly Carbon Reinforced), ETFE/ECTFE (Partly Carbon Fiber Reinforced), FFKM |
Temperature (Metric) Min. | 10°C |
Pump Type | Diaphragm Pump |
Noise Level | 42 dBA |
Flow Rate | 2 m3/hr. |
Motor Speed | 200 to 3000 min-1 |
Control | VACUU·SELECT |
Voltage | 200/230 V |
Frequency | 50-60 Hz |
No. of Pump Heads | 4 |
No. of Stages | 3 |
Maximum Pressure | 1.1 bar |
Max. Vacuum | 2 Mbar (Without Gas Ballast), 4 Mbar (With Gas Ballast) |
Fisherbrand™ Vacuum Pump with UK, US, and Schuko Cables
Quiet in operation with very low vibration. the Fisherbrand™ Vacuum Pump is designed for general duty laboratory applications requiring only rough vacuum or moderate pressure.
Fisherbrand™ FB70155 Pump
Oil-free piston pump. Fisherbrand™ FB70155 Pump designed for general duty laboratory applications requiring only rough vacuum or moderate pressure.
Thermo Scientific™ Fiberboard Box Dividers for Ultra-Low Temperature and Cryogenic Freezers
Organize vial storage within cryo boxes with these fiberboard box dividers.
Thermo Scientific™ Nalgene™ Vent Filters and 50mm Capsules
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Filter aggressive chemicals, including acids and non-aqueous solvents such as those used in GC and HPLC with this in-line syringe filter with PTFE membrane.
Material (Membrane) | PTFE |
---|
Fisherbrand™ Chemical Duty Diaphragm Vacuum Pumps
Use these pumps for a wide range of laboratory applications. Fisherbrand™ Chemical Duty Diaphragm Vacuum Pumps are ideal for applications involving aggressive solvents and acidic vapors.
Fisherbrand™ Vacuum Aspiration Advantage System Accessory, Silicone Hose
Designed for use with Fisherbrand™ Vacuum Aspiration Advantage Systems.
Fisherbrand™ Hose Adapter Kit for Rotary Vane Vacuum Pumps
Use this hose adaptor kit with all Fisherbrand rotary van vacuum pumps. Fisherbrand™ Hose Adapter Kits for Rotary Vane Vacuum Pumps include stainless steel tubing adaptors and clamps for vacuum tight connections.
Fisherbrand™ Vacuum Aspiration Advantage System Accessory, Table Top Stand
Designed for use with Fisherbrand™ Vacuum Aspiration Advantage Systems.
Fisherbrand™ PTFE Filter Membranes
Fisherbrand™ PTFE membrane is hydrophobic filter made of polytetra-fluorethylene laminated with PP layer.
Thickness (Metric) | 0.16 mm |
---|---|
Wettability | Yes |
Type | Plain Disc |
Color | White |
Quantity | 100 Pack |
Material | PTFE |
Hydrophobicity | Hydrophobic |
For Use With (Application) | Sterilizing filtration of gas samples, clarification and filtration of pure solvents, aerosol samplings, filtration of strong Acids and chemical aggressive solutions, venting applications (hospital air conditioning, tank fermentation in microelectronic) |
Fisherbrand™ Aspiration Basic System
Designed for aspirating non-flammable chemical, biological, and medical liquids. Fisherbrand™ Aspiration Basic System is a compact and portable unit with an integrated resistant diaphragm pump, The fluids can be removed easily and very precisely from slides, petri dishes, microplates, cell culture containers and similar vessels.
Vacuum Aspiration Advantage System Accessory, Single-channel Adapter
Designed for use with Fisherbrand™ Vacuum Aspiration Advantage Systems.
Thermo Scientific™ Barnstead™ Smart2Pure™ Water Purification System
Convert tap water to ASTM Type 1 water with this compact, all-in-one water system.
Operating Pressure | 1 to 6 bar |
---|---|
Feedwater Pressure | 1 to 6 bar |
Height (Metric) | 545 mm |
Electrical Requirements | 100/240 V 50/60 Hz |
Net Weight (Metric) | 22 kg |
Particles >0.2µM/mL | <1 |
Feedwater Source | Tap |
TOC Monitor with UV Intensity Monitoring | No |
Width (Metric) | 305 mm |
Type | Water Purification System |
Feedwater Connector | 3/4 in. NPT |
Depth (Metric) | 400 mm |
Voltage | 100/240 V |
Frequency | 50/60 Hz |
Power Consumption | 0.06 kW |
Bacterial Content | <0.01 CFU/mL |
Bacterial retention | 99% |
Feed Water Monitoring | No |