Filtered Search Results
Thermo Scientific™ Multiskan™ FC Microplate Photometer
Multiskan FC microplate photometer is a reliable instrument for a wide variety of research and routine applications. It reads 96- and 384-well plates and is equipped with shaking and incubation capabilities for temperature critical assays. It can be used as a stand-alone instrument or under PC control with intuitive Thermo Scientific SkanIt™ software.
Product Line | Multiskan |
---|
Brand™ Malassez Counting Chamber
Commonly used for counting nematodes or cells in the cerebro-spinal fluid. BRAND™ Malassez Counting Chamber is rectangular, covering an area of 5mm2.
Thermo Scientific™ Matrix™ SepraSeal and DuraSeal Capping Systems
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Accommodate a range of application and storage requirements. These flexible capping options allow automated piercing, visual identification and sterility preference.
Thermo Scientific™ Owl™ Gel Staining Box
Stain, fix and de-stain in the same container with Thermo Scientific™ Owl™ Gel Staining Boxes, offering a convenient, conventional staining method.
Thermo Scientific™ Ponceau S Staining Solution
Ponceaus S Staining Solution is a ready-to-use membrane stain for evaluating the transfer efficiency of a western blot.
Formulation | 0.1% (w/v) in 5% acetic acid |
---|---|
For Use With (Application) | Western Blotting |
Detection Method | Colorimetric |
Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer
Perform both basic and complex analyses with the Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer, an intuitive, reliable solution for education or in the lab.
Photometric Accuracy | ±0.002 A (0 to 0.3 A), 0.5% of ABS reading (0.301 A to 2.5 A) |
---|---|
Connections | USB-A, USB-B |
Scan Speed | Automatic – up to 1200 nm/min. |
Printer Included | Thermal printer accessory with 80 mm width paper |
Noise | ≤0.001A at 0A |
Languages | English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic |
Detector Type | Silicon Photodiode |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100mm pathlength Available accessory for test-tubes up to 25mm diameter and 150mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Stray Light | <0.1%T at 340 nm and 400 nm Measured using glass cutoff filters or NaNO2 at 340 nm |
Optical Design | Single Beam |
Photometric Repeatability | ± 0.002 A Measured at 1.0 A at 546 nm |
Weight (Metric) | 7.5 kg |
Wavelength Data Interval | 1 nm |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/250 V, 50/60 Hz |
Warranty | 2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase |
Photometric Range | -3A to +3A |
Wavelength Repeatability | < ±1 nm |
Spectral Bandwidth | 5 nm |
Baseline Flatness | <0.003 A, 325 to 1000 nm, smoothed |
Photometric Display | -3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C |
Type | Visible Spectrophotometer |
Dimensions (L x W x H) | 35.5x 38.5x 19.5 cm |
Wavelength Accuracy | ±2 nm |
Lamp Life | 1000 hrs. |
Keypad | Tactile rubber 23 keys with numeric keypad |
Drift | <0.002 A/hr. (At 500 nm after 2 hr. warmup.) Typical <0.004 A/hr. after 1 hr. warmup |
Wavelength Range | 325 to 1100 nm |
Product Line | GENESYS 30 |
Display | 5 in. 32-bit Color Display, 800 x 480 pixels |
Thermo Scientific™ Owl™ EasyCast™ B2 Mini Gel Electrophoresis Systems
Achieve superior flexibility in a small footprint with our B2 mini gel electrophoresis systems.
Height (Metric) | 9.5 cm |
---|---|
Width (English) | 7.06 in. |
Length (Metric) | 24.5 cm |
Width (Metric) Gel | 12 cm |
Length (English) | 9.63 in. |
Width (Metric) | 18 cm |
Length (Metric) Gel | 14 cm |
Gel Size | Mini |
Sample Size | 8 to 48 |
Type | Mini Gel Electrophoresis System |
Dimensions (L x W x H) | 9.63 x 7.06 x 3.75 in. (24.5 x 18 x 9.5 cm) |
Certifications/Compliance | CE marked |
Height (English) | 3.75 in. |
Volume (Metric) Buffer | 800 mL |
Product Line | Owl |
Thermo Scientific™ Ethidium Bromide Solution (0.625 mg/mL)
Visualize DNA fluorescently in a variety of molecular biology applications using these dilute (0.625mg/mL) or concentrated (10mg/mL) ethidium bromide solutions.
Applied Biosystems™ MicroAmp™ Adhesive Film Applicator
Use to form a secure seal between a microplate and an adhesive film
Thermo Scientific Chemicals Acrylamide, 98.5%, extra pure
CAS: 79-06-1 Molecular Formula: C3H5NO Molecular Weight (g/mol): 71.08 MDL Number: MFCD00008032 InChI Key: HRPVXLWXLXDGHG-UHFFFAOYSA-N Synonym: Ethylenecarboxamide,2-Propenamide PubChem CID: 6579 ChEBI: CHEBI:28619 IUPAC Name: prop-2-enamide SMILES: NC(=O)C=C
PubChem CID | 6579 |
---|---|
CAS | 79-06-1 |
Molecular Weight (g/mol) | 71.08 |
ChEBI | CHEBI:28619 |
MDL Number | MFCD00008032 |
SMILES | NC(=O)C=C |
Synonym | Ethylenecarboxamide,2-Propenamide |
IUPAC Name | prop-2-enamide |
InChI Key | HRPVXLWXLXDGHG-UHFFFAOYSA-N |
Molecular Formula | C3H5NO |
Thermo Scientific Chemicals Acrylamide/Bisacrylamide Solution (40%, 37.5:1)
Acrylamide/Bisacrylamide Solution (40%, 37.5:1), also known as bioAcryl-P (40%, 37.5:1), is a premixed solution containing acrylamide and N,N'-methylenebisacrylamide (in a ratio of 37.5:1, respectively) used for preparing protein DNA gels.
Health Hazard 3 | P201-P202-P260-P264b-P270-P272-P280-P281-P301+P312-P302+P352-P305+P351+P338-P308+P313-P330-P333+P313-P362-P501c |
---|---|
MDL Number | MFCD00080848 |
Color | Colorless |
Health Hazard 2 | GHS H Statement H340-H350-H372-H361-H302-H315-H319-H317 May cause genetic defects. May cause cancer. Causes damage to organs through prolonged or repeated exposure. Suspected of damaging fertility or the unborn child. Harmful if swallowed. Causes skin irritation. Causes serious eye irritation. May cause an allergic skin reaction. |
Solubility Information | It is soluble in water. |
Health Hazard 1 | H302-H315-H317-H319-H340-H350-H361f-H372 |
Physical Form | Liquid |
UN Number | UN3426 |
DOT Information | Transport Hazard Class: 6.1; Packing Group: III; Proper Shipping Name: ACRYLAMIDE SOLUTION |
Chemical Name or Material | Acrylamide/Bisacrylamide 37.5:1 |
TSCA | Yes |
Recommended Storage | Keep cold |
Concentration | 40% soln |
Thermo Scientific™ GENESYS™ 40/50 Vis/UV-Vis Spectrophotometers
For teaching labs or quality control experts who require ruggedness, ease-of-use and software capability in UV-Vis spectrophotometry.
Thermo Scientific™ Pierce™ Reversible Protein Stain Kit for PVDF Membranes
Reversibly stain proteins on nitrocellulose or PVDF membrane after transfer from polyacrylamide gels with this sensitive Ponceau S alternative.
Thermo Scientific Chemicals Acrylamide (30%) Solutions
CAS: 79-06-1 Molecular Formula: C3H5NO Molecular Weight (g/mol): 71.08 MDL Number: MFCD00008032 InChI Key: HRPVXLWXLXDGHG-UHFFFAOYSA-N PubChem CID: 6579 ChEBI: CHEBI:28619 IUPAC Name: prop-2-enamide SMILES: NC(=O)C=C
PubChem CID | 6579 |
---|---|
CAS | 79-06-1 |
Molecular Weight (g/mol) | 71.08 |
ChEBI | CHEBI:28619 |
MDL Number | MFCD00008032 |
SMILES | NC(=O)C=C |
IUPAC Name | prop-2-enamide |
InChI Key | HRPVXLWXLXDGHG-UHFFFAOYSA-N |
Molecular Formula | C3H5NO |
BioAcryl-P (30%, 29:1), Thermo Scientific Chemicals
BioAcryl-P (Acrylamide/Bisacrylamide 29:1, CAS # 25034-58-6) is a powder-based formula used to create the gel matrix necessary for electrophoresis experiments.
Health Hazard 3 | P201-P202-P260-P264b-P270-P271-P272-P280-P281-P301+P312-P302+P352-P304+P340-P305+P351+P338-P308+P313-P330-P333+P313-P362-P501c |
---|---|
MDL Number | MFCD00080848 |
Color | Colorless |
Health Hazard 2 | GHS H Statement H340-H350-H372-H361-H302-H315-H319-H317 May cause genetic defects. May cause cancer. Causes damage to organs through prolonged or repeated exposure. Suspected of damaging fertility or the unborn child. Harmful if swallowed. Causes skin irritation. Causes serious eye irritation. May cause an allergic skin reaction. |
Solubility Information | Difficult to mix. |
Health Hazard 1 | H302+H332-H315-H317-H319-H340-H350-H361f-H372 |
Physical Form | Liquid |
UN Number | UN3426 |
DOT Information | Transport Hazard Class: 6.1; Packing Group: III; Proper Shipping Name: ACRYLAMIDE SOLUTION |
Chemical Name or Material | Acrylamide/Bisacrylamide 29:1 |
TSCA | Yes |
Recommended Storage | Keep cold |
Concentration | 30% soln |