Distillation Labware
Distillation Labware
Glassware and replacement parts designed to carry out distillations in laboratory settings; includes condensers, distillation heads, receivers, etc. Products are available for various scales and for specialty distillations.
Distillation is a process used widely in the laboratory or in wider working environments for separating or purifying liquids or liquid mixtures based on the different boiling points of individual components.
Distillation Applications:
• Separation and purification of miscible liquid mixtures in organic chemistry
• Drying of solid residues and/or solvent removal
• Fractional distillation of liquids from polymers and petroleum products
• Removal of particulates or other solid contaminants
• As part of a water purification system for production of distilled water for laboratory use
• Specialist steam distillation-based applications such as Kjeldahl analysis of nitrogen and proteins in food, beverage, or environmental samples
What Types of Distillation Equipment Are Available?
Conventional distillation apparatus, typically comprising individual, jointed borosilicate glassware components assembled by the user (depending upon the application), using appropriate clamps, stands, and supports. Most conventional distillation assemblies combine a round-bottomed distilling flask to contain and heat the liquid(s) that require purification, fitted with a stoppered or jointed neck to which is attached a downward-sloping, inclined side-arm for connection to a condensing unit to cool the heated vapors back down to their liquid state. Heating mantles are the preferred heat source for improved temperature control. These conventional distillation units are also available supplied complete and ready-assembled for added convenience and ease of use.
Specialized automated distillation equipment, notably units designed for the determination of volatile acidity and alcoholic strength by volume in wines, musts, and alcoholic beverages, and units designed for Kjeldahl nitrogen or protein determinations.
- (5)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (3)
- (3)
- (1)
- (1)
- (1)
- (5)
- (2)
- (1)
- (3)
- (3)
- (1)
- (1)
- (4)
- (3)
- (1)
- (4)
- (2)
- (1)
- (1)
- (4)
- (4)
- (7)
- (4)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (8)
- (1)
- (15)
- (1)
- (1)
- (3)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (3)
- (3)
- (2)
- (1)
- (1)
- (3)
- (1)
- (2)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (2)
- (6)
- (1)
- (4)
- (1)
- (3)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (5)
- (1)
- (2)
- (1)
- (1)
- (3)
- (1)
- (1)
- (1)
- (1)
- (7)
- (6)
- (4)
- (1)
- (1)
- (3)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (3)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (1)
Filtered Search Results
DWK Life Sciences Kimble™ Kontes™ Distilling Vigreux Column with Standard Taper Joints
Vigreux distilling column with indentations over the entire length for improved vapor-liquid contact. A range of column lengths (130mm, 150mm or 300mm) for a variety of joint sizes.
Type | Vigreux Column |
---|---|
Certifications/Compliance | USP Type I, ASTM E438, Type I, Class A |
Type | Straight Adapter with NS Stopcock |
---|---|
Material | Duran Glass |
Quickfit™ Borosilicate Glass Still Head Adapter
Connect a flask with a condenser in a distillation assembly. The QuickFit™ still head adapter is designed to accept a thermometer as well.
Type | Still Head Adapter |
---|---|
Material | Borosilicate Glass |
For Use With (Application) | Connecting flask and condenser |
Quickfit™ Borosilicate Glass Vigreux Fractionating Column
Popular and easy-to-use fractionating column using a combination of horizontal and angled indentations. Quickfit™ Borosilicate Glass Vigreux Fractionating Column has a significantly increased column surface area for greater efficiency.
Quickfit™ Still Head Vertical Recovery Adapter
Used in distillation assemblies in which the condenser is assembled in the vertical mode
Type | Vertical Recovery Still Head |
---|---|
Material | Borosilicate Glass |
Certifications/Compliance | ISO 3585 |
For Use With (Application) | Used in distillation assemblies in which the condenser is assembled in the vertical mode |
Lenz Laborglasinstrumente™ Splash Heads Acc. to Stutzer, Straight
For placement onto distillation flasks for separation of drops. Lenz Laborglasinstrumente™ Splash Heads Acc. to Stutzer, Straight, are manufactured from durable Duran™ glass tubing.
Type | Straight Splash Heads |
---|---|
Material | Duran Glass |
For Use With (Application) | For separation of drops (Direct placement onto distillation flasks) |
DWK Life Sciences Kimble™ Kontes™ Flask Inlet Adapter, Monier-Williams, 24/40 Joint
Component Parts of Monier-Williams Sulfites Distillation Apparatus which is used for the determination of free sulfite and a reproducible portion of the bound sulfites in food, such as the carbonyl addition products.
DWK Life Sciences Kimble™ Kontes™ MIDI-VAP 4000 Component Replacement Parts
Component parts for both ammonia and phenol distillation system
For Use With (Application) | Distillation systems |
---|
DWK Life Sciences Kimble™ Kontes™ Monier–Williams Sulfites Distillation Apparatus
For the determination of free sulfite and a reproducible portion of the bound sulfites in food, such as the carbonyl addition products.