Gel Filtration Media and Columns
Gel Filtration Media and Columns
- (3)
- (2)
- (2)
- (1)
- (3)
- (1)
- (3)
- (2)
- (1)
- (6)
- (1)
- (2)
- (8)
- (6)
- (3)
- (2)
- (7)
- (2)
- (1)
- (7)
- (2)
- (11)
- (3)
- (6)
- (1)
- (1)
- (3)
- (6)
- (1)
- (2)
- (1)
- (2)
- (2)
- (1)
- (1)
- (2)
- (3)
- (1)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (16)
- (2)
- (9)
- (2)
- (2)
- (10)
- (4)
- (1)
- (2)
- (2)
- (1)
- (2)
- (1)
- (2)
- (5)
- (1)
- (2)
- (1)
- (3)
- (3)
- (2)
- (2)
- (1)
- (8)
- (1)
- (5)
- (1)
- (5)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (5)
- (1)
- (1)
- (1)
- (1)
- (4)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (3)
Filtered Search Results
Cytiva Superdex™ 200 Increase 10/300 GL Prepacked Tricorn™ Columns
For size exclusion chromatography and analysis of proteins with molecular weights between 10,000 and 600,000. Cytiva Lifescience™ Superdex™ 200 Increase 10/300 GL Prepacked Tricorn™ Columns are designed for small scale preparative purification.
Thermo Scientific™ POROS™ GoPure™ 50 D Pre-packed Column, 0.5 x 5 cm, 1 mL
Thermo Scientific™ POROS™ GoPure™ 0.5 cm pre-packed columns are intended for the screening of POROS ion exchange resins or for small scale purification.
Cytiva Gel Filtration Calibration Kits
Calibrate gel filtration columns simply, reliably. Cytiva Life Sciences™ Gel Filtration Calibration Kits contain a well-defined series of protein standards.
Content And Storage | 2° to 8°C |
---|---|
Product Type | Calibration Kit |
For Use With (Equipment) | High-resolution media and prepacked column |
Quantity | Each |
For Use With (Application) | Calibration of high-resolution gel filtration media and column such as Superdex™, Superose and Sephacryl |
Cytiva HiTrap™ Heparin HP Columns
Purify DNA-binding proteins, coagulation factors, lipoproteins and protein synthesis factors. Cytiva Life Sciences™ HiTrap™ Heparin HP Columns are prepacked with Heparin Sepharose™ High Performance for high-resolution purification.
Particle Size | 34 μm |
---|---|
Ligand Type | 10mg Heparin/mL medium |
Height (Metric) | 2.5cm |
Content And Storage | 4° to 30°C |
pH Range | 5 to 10 |
Product Type | Heparin HP Column |
For Use With (Equipment) | Syringe, peristaltic pump or liquid chromato graphy system such as AKTA™ design or FPLC system |
Sample Type | DNA-binding Proteins, coagulation facto rs, Lipoproteins and Protein synthesis facto rs |
Material | Polypropylene |
For Use With (Application) | Purification of Antithrombin III, coagulation facto rs and other Plasma Proteins |
Support Type | 6% Highly Cross-linked Agarose |
Max. Pressure | 42psi |
Height (English) | 0.98 in. |
Cytiva HiTrap™ NHS-Activated HP Columns
Couple ligands containing primary amines easily. Cytiva Life Sciences™ HiTrap™ NHS-Activated HP Columns are prepacked with NHS activated Sepharose™ High Performance.
Particle Size | 34 μm |
---|---|
Ligand Type | 10μM NHS groups/mL medium |
Height (Metric) | 2.5cm |
Content And Storage | 4° to 8°C |
pH Range | 3 to 12 |
Product Type | NHS-Activated HP Column |
For Use With (Equipment) | Syringe, peristaltic pump or liquid chromato graphy system such as AKTA™ design or FPLC system |
Material | Polypropylene |
For Use With (Application) | Preparative affinity chromato graphy, easy coupling of ligands containing primary Amines |
Support Type | 6% Highly Cross-linked Agarose |
Max. Pressure | 42psi |
Height (English) | 0.98 in. |
Cytiva Sephadex™ LH-20
Use for molecular sizing of natural product such as steroid, terpenoid, lipid, low molecular weight peptide. Cytiva Life Sciences™Sephadex™ LH-20 is a liquid chromatography media useful to analytical and industrial scale for preparation of closely related molecular species.
Particle Size | 18 to 111 μm in dry form |
---|---|
Height (Metric) | 30cm |
Flow Rate | 720 cm/hr. |
Content And Storage | 4 to 30°C |
Format | Solid Spherical Bead |
pH Range | 2 to 13 |
Product Type | Sephadex LH-20 Media |
Sample Type | Steroid, Terpenoid, Lipid, low molecular weight Peptide |
Diameter (Metric) Inner | 2.6cm |
For Use With (Application) | For fractionation of lipids, hormones, vitamins, and other small biomolecules in polar organic solvents and aqueous solvent mixtures |
Support Type | Hydroxypropylated, cross-linked Dextran |
Max. Pressure | 25-45 cm/h, pressure drop cm H2O/bed height=2, beh height 30 cm, 2.6 cm i.d. |
Height (English) | 11.81 in. |
Cytiva Superdex™ 200 Increase 5/150 GL Prepacked Tricorn™ Columns
For size exclusion chromatography and analysis of proteins with molecular weights between 10,000 and 600,000. Cytiva Lifescience™ Superdex™ 200 Increase 5/150 GL Prepacked Tricorn™ Columns are designed for small scale preparative purification.
Cytiva HiPrep™ Sephacryl™ HR Prepacked Gel Filtration Columns
For reproducible protein purification, separating polysaccharides, macromolecules with extended structures and small plasmids
Particle Size | 25 to 75 μm |
---|---|
Height (Metric) | 60cm |
pH Range | 3 to 11 |
Product Type | Sephacryl HR Pre-packed Gel Filtration Column |
For Use With (Equipment) | Low to medium pressure AKTA™ systems or pumped chromatography systems |
Sample Type | Polysaccharides, macromolecules with extended structures and even small plasmids |
Quantity | Each |
Material | Polypropylene |
For Use With (Application) | Reproducible Protein purification, separating Polysaccharides, macromolecules with extended structures and small plasmids |
Support Type | Allyl Dextran and N,N'-methylenebisacrylamide |
Max. Pressure | 1.5 bar [0.15 MPa] (22 psi) |
Height (English) | 23.62 in. |
Cytiva Sephacryl™ S-100 High Resolution Media
Hydrophilic, rigid allyl dextran/bisacrylamide matrix for fast and reproducible purification of proteins, polysaccharides and other macromolecules
Cytiva Sephadex™ G-25 Media
Use of Sephadex™ is well established as a gel filtration medium for desalting and buffer exchange in industrial applications. Cytiva Life Sciences™ Sephadex™ G-25 Media quickly desalts, removes contaminants and transfers to a new buffer in a single step.
Height (Metric) | 30cm |
---|---|
Content And Storage | 4 to 30°C, dry resins. Used resins 4 to 8 °C in 20% Ethanol or 0.01 M NaOH |
Bed Volume | 4 to 6mL/g in Distilled Water |
Format | Solid Spherical Bead |
pH Range | 2 to 13 |
Product Type | Sephadex G-25 Media |
Diameter (Metric) Inner | 2.6cm |
For Use With (Application) | Desalting and Buffer exchange and removal free label in industrial applications |
Support Type | Cross-linked Dextran |
Height (English) | 11.81 in. |
Height (Metric) | 5 to 15cm |
---|---|
Content And Storage | 4° to 30°C |
Format | Solid Spherical Bead |
Product Type | Sephadex Ion Exchange Media |
For Use With (Equipment) | Column or Batch Techniques |
For Use With (Application) | Separating and purifying Proteins, Polypeptides, Nucleic Acids and other charged biomolecules by using column or batch techniques |
Support Type | Cross-linked Dextran |
Height (English) | 2 to 5.9 in. |
Cytiva Superdex™ 200 Prep Grade
Produce separation medium with high selectivity and resolution. Cytiva Life Sciences™ Superdex™ 200 Prep Grade for purifying proteins of fractionation range: 10000 to 600000D
Cytiva HiTrap™ Blue HP Columns
For purifying albumin, enzymes including NAD+ and NADP+, coagulation factors, interferons and related proteins
Particle Size | 34 μm |
---|---|
Height (Metric) | 2.5cm |
Content And Storage | 4° to 30°C |
pH Range | 4 to 12 |
Product Type | Blue HP Columns |
For Use With (Equipment) | Syringe, peristaltic pump or liquid chromato graphy system such as AKTA™ design or FPLC system |
Sample Type | Albumin, interferon, a broad range of nucleotide-dependent Enzymes, a2-macroglobulin, coagulation facto rs and related Proteins |
Material | Polypropylene |
For Use With (Application) | Purifying wide range of biomolecules, including albumin, interferon, a broad range of nucleotide-dependent Enzymes, alpha2-macroglobulin, coagulation facto rs and related Proteins |
Support Type | 6% Highly Cross-linked Agarose |
Max. Pressure | 42psi |
Height (English) | 0.98 in. |